800.748.6285

ISAscale

ISAscale

http://www.isabellenhuette.de/en/precision-measurement/

Renowned for our expertise in the field of precision measurement in high-current applications, Isabellenhütte has been a leading global provider of advanced measuring systems for many years. Marketed under the ISAscale® brand, our precision measuring systems offer exceptionally high performance. Our commitment to achieving the ultimate in precision is combined with ease of use and a high degree of variability.

 

 
Series: IVT-MOD Series IPC-MOD Series IHC Series
  ISAscale ® / Current Voltage Temperature ISAscale ® Phase Current ISAscale ® High Current
       
Sensing Functions: DC Current, Voltage and Temperature AC Current  AC, DC and Mixed Current 
Accuracy: 0.1%  0.2%  0.3% (DC)
Current Range Amps: 100 - 2500 100 - 2500  300 - 1000
       
Applications: High Voltage Battery Monitoring  Inverters in Electric Drives Laboratory Use
  Lithium-ion Battery Monitoring Renewable Energy Applications Battery Buffered Power Supplies
       
Distinctives: 3 Voltage Channels to monitor
intermediate cirucit voltages/relays
High Speed Phase Current Sensing
up to 20 MHz
Reactive, Apparent & Real Power Measurement
 
Hardware Trigger
Insulation Voltage 1,000 VRMS,
1500 VDC

Oscilloscope Mode
  Overcurrent Functionality   PC Software Included
 
CAN Interface

 
Isolation Voltage 250 VDC/AC,
3.5 kV Peak
Power Supply with Galvanic Isolation    
  Connector Options Evaluation Kits  

 

IVT - MOD    IVT - 100 IVT - 300 IVT-500 IVT - 1000 IVT - 2500

DC Current, Voltage and Temperature Measurement
 




Nominal
Measurement Range

A

±100

±300

±500

±1000

±2500
Power Loss W <3 <9 <9 <20 <32
Overcurrent 
Measurement Range

A

±800

±2500

±6900

±12200

±48000
Extended Load
(max. time)
           
5 min. A ±120 ±320 ±730 ±1100 ±2700
30s A ±200 ±430 ±860 ±1400 ±3200
10s A ±300 ±600 ±1000 ±2000 ±4300
1s A ±900 ±1600 ±2700 ±5500 ±11300
200ms A ±2000 ±3600 ±6000 ±12000 ±24000
Initial Accuracy %rdg ±0.1 ±0.1 ±0.1 ±0.1 ±0.1
Offset mA 8 25 75 125 500
Linearity % of range 0.01 0.01 0.01 0.01 0.01
Noise mA (RMS) 5 15 40 70 280
Resolution mA 3 10 27 47 186
             
IVT-MOD
Voltage Measurement

 
   
All Series
IVT-100 to IVT-2500
   
             
Nominal Measurement Range
V
   
±600
   
Extended Range 
(non-linear)

V
   
±800
   
Initial Accuracy %rdg     0.1    
Offset mV     100    
Linearity % of range     0.01    
Noise mV (rms)     60    
Resolution mV     30    


Connector Options:
   

 
      Voltage Measurement


CANbus 
Connector

CANbus
Termination
 
             

 

IPC - MOD    IPC - 100 IPC - 300 IPC - 500 IPC - 1000 IPC - 2500

AC Current
Sensing Module



M8 thread Connector




 

 
 

RJ45 thread connector
 
Nominal
Measurement Range

A

±100

±300

±500

±1000

±2500
Power Loss W <3 <9 <9 <20 <32
Overcurrent 
Measurement Range
(linear)

A

±170

±520

±1400

±2450

±9500
Overcurrent Measurement Range
(nonlinear)

A

±210

±650

±1750

±3100

±12500
Extended Load
(max. time)
           
5 min. A ±120 ±320 ±730 ±1100 ±2700
30s A ±200 ±430 ±860 ±1400 ±3200
10s A ±300 ±600 ±1000 ±2000 ±4300
1s A ±900 ±1600 ±2700 ±5500 ±11300
200ms A ±2000 ±3600 ±6000 ±12000 ±24000
Initial Accuracy @ 20°C %rdg ±0.2 ±0.2 ±0.2 ±0.2 ±0.2
Initial Accuracy over
operating temp range
%rdg ±0.5 ±0.5 ±0.5 ±0.5 ±0.5
Offset %rng 8 25 75 125 500
Noise
(peak to peak)

digit

≤20

≤20

≤20

≤20

≤20
Resolution mA 7 20 55 95 380

 

IPC - MOD Evaluation Kit
   
Hardware - 4 Filter elements: TI AMC 1210 (sinc1, sinc2, sinc3, sincfast)
  - Open housing
Software - Software for evaluation on a PC via Ethernet
  - Configuation of OCR and filter type
  - Display of reading in a current-time-diagram or digit-time -diagram
  - Storage of measurement in CSV file
  - Output of frequency spectrum as a diagram
Kit Contents - Evaluation Board  
  - Softwware on a USB flash drive
  - User Manual
  - 24V Power supply (100V-240V Input)
  - 2 ethernet cables
  - 1 IPC-MOD sensor (nominal current range of your choice)
  - Aluminium box for storage

 

IHC Series   IHC - 01 IHC - 03

AC, DC and Mixed Current
Sensing Module
 
Operating Conditions      
Continuous Current A ±1,000 ±300
Measurement V AC/DC
(safety precaution - only 
≤ 250 V to earth)

V
250 VAC phase to earth
500 VAC phase to phase

±500 VDC
250 VAC phase to earth
500 VAC phase to phase

±500 VDC
Operating Temperature C -20 to +75 -20 to +75
Power Supply VDC, mA 24 DC, 40 mA 24 DC, 40 mA
Extended Operating Conditions      
Pulse Current leff AC/DC tpulse ≤ 1 sec.
duty cycle 
≤ 0.5%
A ±2,000 ±600
Power supply   21.....26 V DC, 50 mA 21.....26 V DC, 50 mA
Pulse voltage Upeak
tpulse ≤ 1 sec, duty cycle ≤ 10%

V

±1,000

±1,000
Specifications      
Accuracy DC Current Measurement   ±(0.3 % of rdg + 0.01 % of rng)   ±(0.1 % of rdg + 0.01 % of rng)
Accuracy AC current measurement   ±(1 % of rdg + 0.01 % of rng)     ±(0.3 % of rdg + 0.01 % of rng)
Resolution current measurement[2] A 0.003…0.090    0.001…0.030 A
Accuracy DC voltage measurement   ±(0.1 % of rdg + 0.005 % of rng) ±(0.1 % of rdg + 0.005 % of rng)
Accuracy1 AC voltage measurement   ±(0.3 % of rdg + 0.005 % of rng) ±(0.3 % of rdg + 0.005 % of rng)
Resolution voltage measurement2 V 0.001…0.030  0.001…0.030 
Linearity error ppm < 100  < 100 
General Information      
Isolated Interface   RS232/RS485 RS232/RS485
Data transmission rate [1] msec 0.500…4,200  0.500…4,200 
Integration time AC measurement msec 100  100 
Integration time DC measurement msec 5…10,000  5…10,000 
Frequency range AC measurement Hz 30…70  30…70 
Internal heat resistance Rth K/W < 0.5  < 0.5 
       
  • Open housing
  • Open housing

View all ISAscale partsRequest a quote or Contact us for additional information.